Continuous Wrist strap Monitor Z106 & Workstation Monitor Z107

Category:

Z107

The Model Z107 has independent circuitry to continuously monitor the Wrist Strap and Work Surface.
WRIST STRAP
This section monitors the wrist strap to detect loss of continuity between operator and monitor.  Broken coil cords and improper contact with the skin are detected instantly to alert the operator.
 WORK SURFACE (MAT)
The work surface is monitored and a warning is given if Surface-to-Ground resistance exceeds the safe value
SPECIFICATIONS
Pass Threshold :  under 10 Megohms for Wrist Strap.
:  under 10 Megohms for MAT
Indications :  Pass  –  Green LED
Fail  –  Flashing Red LED for Wrist Strap
Steady Red LED for MAT
Audible Alarm for Fail mode.
Power supply :  6VDC 100ma
Dimensions :  110 x 60 x 32 mm
Weight :  75 gms
Warranty :  One year
Conformance :  BS EN 100 015 – 1 (advisory only)

Z106

Wrist Straps are the first line of defence against  electrostatic charge build-up on the human body.
This instrument continuously monitors the wrist strap to detect loss of continuity between operator and monitor and/or proper grounding. Broken coil cords and improper contact with the skin are detected instantly to alert the operator.
SPECIFICATIONS :
Dimensions in mm :  80 x 60 x 27
Weight :  50 gms
Monitoring :  By capacitive method
Trigger level :  Virtual resistance to ground over 10 Megohms
Fault warning :  Both audio & visual
Indications :  3mm DUAL LED
Audible Alarm for Fail mode
Power to Adaptor :  230V AC 50/60 Hz.
Power to Monitor :  Special Adaptor – DC 6V 100ma
Warranty :  One year
Conformance :  BS EN 100 015 – 1 (advisory only)